Clack
Regeneration Not Initiating
The Clack water softener does not start regeneration at the programmed time.
Advertisements
Possible Causes
Incorrect time of day setting, Regeneration mode set to “off” or demand-only with no usage, Power interruptions resetting the clock, Faulty control board timer circuit
How to Fix / Troubleshooting
Safety: No internal electrical work is required for basic checks.
Steps:
- Verify time of day: Check that the controller’s time matches the actual time and that AM/PM is correct. Adjust if necessary.
- Check regeneration mode: Confirm that the system is set to the desired mode (time clock, metered immediate, or metered delayed). If set to demand-only and water usage is low, regeneration may not occur frequently.
- Review day override: Ensure that a maximum day override is programmed so the unit regenerates at least every set number of days, even with low usage.
- Power stability: If frequent outages occur, consider using a small UPS or surge protector to maintain clock settings.
- Manual test: Initiate a manual regeneration. If the valve will not start a cycle at all, the control board or keypad may be faulty and require replacement.
Note: After any programming change, observe the next scheduled regeneration to confirm proper operation.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Clack Electronic Control Board
Check Price on Amazon