No Regen
Culligan
Regeneration Inhibit or Scheduling Fault
Display shows “No Regen” or the unit never regenerates automatically.
Advertisements
Possible Causes
Regeneration disabled in programming, incorrect time of day, flow meter not counting usage, control board logic fault.
How to Fix / Troubleshooting
Safety: No plumbing work is required for basic checks; you will be working only with the control panel.
- Check time and day: Ensure the time of day and day of week are set correctly on the Culligan control.
- Verify regen mode: Enter the programming menu and confirm that automatic regeneration is enabled (metered or time clock mode) and that the capacity and hardness are set correctly.
- Check flow meter operation: Run water and confirm that the display shows flow and usage. If not, troubleshoot the flow meter.
- Manual regeneration test: Start a manual regeneration. If the unit regenerates manually but never automatically, the scheduling or meter input is at fault.
Advertisements
Repair Difficulty
Easy
2/5