Foridra Water Hammer / Rapid Valve Operation

Softener makes loud banging or hammering noises during regeneration

Advertisements

Possible Causes

High inlet pressure, Fast-closing Foridra valve, Lack of water hammer arrestor, Loose plumbing supports

How to Fix / Troubleshooting

Safety: High pressure and water hammer can damage plumbing. Consider consulting a plumber if you are unsure.

  • Measure pressure: Use a gauge to check household pressure. If it is above 80 psi, install or adjust a pressure reducing valve.
  • Secure pipes: Add or tighten pipe clamps and supports near the Foridra softener to reduce movement.
  • Install hammer arrestor: Fit a water hammer arrestor on the line feeding the softener or near problematic fixtures.
  • Adjust cycle settings: If possible, reduce the backwash flow rate or adjust cycle parameters according to Foridra guidelines to soften transitions.
Advertisements

Repair Difficulty

Easy 2/5
Advertisements