Possible Causes

Overheating compressor tripping the overload, Faulty start relay, Incorrect voltage supply, Control board logic fault, Blocked condenser airflow

How to Fix / Troubleshooting

Safety: Unplug the unit before servicing rear components. The compressor and lines may be hot.

  • Clean condenser coil and ensure airflow: Remove dust and debris from the condenser and verify that the condenser fan is running properly.
  • Check voltage: Use a multimeter to confirm that the outlet supplies stable voltage within the range specified by Amana.
  • Inspect start relay and overload: Replace them if they show signs of overheating or test out of spec.
  • Allow cooling: If the compressor is extremely hot, let it cool for an hour and then restart. Persistent overheating suggests a failing compressor or a blocked system, requiring professional service.
  • Control board evaluation: If the compressor is cool but still short cycles, the control board may be misreading the temperature or malfunctioning and may need replacement.