BODEGA43
Temperature Calibration / Sensor Drift
The displayed temperature is significantly different from the actual temperature measured with a thermometer.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Aging NTC sensor, poor sensor placement, loose sensor mounting on evaporator, control board calibration error.
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing any sensors.
Steps:
- Verify with reliable thermometer: Place a calibrated thermometer in the center of the cabinet, away from walls, and compare the reading after several hours of stable operation.
- Inspect sensor placement: Ensure the cabinet sensor is properly clipped to its mounting point and is not touching the evaporator directly, unless specifically designed to do so.
- Replace sensor: If the sensor consistently reads off by a large margin, replace the cabinet temperature sensor (NTC).
- Control calibration: Some models allow minor calibration via service mode; refer to the BODEGA43 documentation or contact support.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cabinet Temperature Sensor (NTC Probe)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements