Brandt
Interior Light Circuit Failure
Interior light does not turn on when the door is opened, but the cooler otherwise works normally.
Advertisements
Possible Causes
Burned-out LED module or bulb, Faulty door switch, Loose light wiring connector, Failed light driver on control board
How to Fix / Troubleshooting
Safety first: Unplug the cooler before replacing any light components.
Steps to restore interior lighting:
- 1. Check door switch: Verify that the door switch (mechanical or magnetic) is functioning. If the display indicates door open/closed correctly, the switch is likely fine.
- 2. Access light assembly: Remove the light cover inside the cabinet (usually clipped or screwed). Inspect the LED module or bulb.
- 3. Replace light source: If the LED module is visibly damaged or darkened, replace it with a Brandt-compatible LED light assembly.
- 4. Check wiring: Ensure the light connector is firmly seated and wires are not damaged.
- 5. Control board: If a new light does not work and the door switch is good, the light driver circuit on the main PCB may be faulty and require board replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
LED Light Module
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements