E11
Grundig
Upper/Lower Zone Temperature Sensor Fault (Dual-Zone Models)
Display shows E11 and the dual-zone wine cooler cannot control one of the zones correctly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed NTC sensor in upper zone, Failed NTC sensor in lower zone, Wiring harness damage between the zones and the PCB, Defective multi-channel sensor input on the main board
How to Fix / Troubleshooting
Safety: Unplug the dual-zone wine cooler before removing interior panels.
- Identify affected zone: Compare displayed temperatures and actual bottle temperatures in each zone to determine which zone is displaying incorrect readings.
- Access zone sensor: Remove shelves and the inner panel for the affected zone to locate the NTC sensor on the wall or evaporator cover.
- Inspect and test sensor: Check for physical damage and measure resistance at known temperatures. Replace the sensor if readings are out of range.
- Check harness to PCB: Follow the sensor cable to the main board, ensuring no pinched or broken sections and that the connector is secure.
- Replace sensor: Fit a new Grundig zone NTC temperature sensor for the faulty zone.
- Board diagnosis: If both sensors test as functional but the E11 error persists, the multi-channel sensor input on the main PCB may be defective and require replacement.