E14
Grundig Compressor Temperature Sensor or Overheat Protection Fault

Display shows E14 and the compressor cycles rapidly or not at all, with erratic temperature control.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective compressor shell temperature sensor, Sensor detached from the compressor body, Wiring damage near the compressor, Main PCB misinterpreting the sensor signal

How to Fix / Troubleshooting

Safety: Unplug the appliance. The compressor and nearby components may be hot; allow them to cool.

  • Locate compressor sensor: Some Grundig models use an NTC sensor clipped to the compressor shell. Inspect its position and attachment.
  • Check wiring: Ensure the sensor cable is intact and not touching hot or moving parts.
  • Test sensor: Measure resistance at room temperature and compare to Grundig specifications. Replace the sensor if readings are abnormal.
  • Reattach sensor: If the sensor has come loose, reclip it firmly to the compressor using the original bracket or clip.
  • Replace sensor or PCB: Install a new Grundig compressor temperature sensor if defective. If the sensor is functional but the E14 error persists, the main PCB may need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Compressor Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements