LG
Door Switch or Light Control Failure
Wine cooler interior light stays on all the time, even with the door closed; the cabinet may get warm near the light.
Advertisements
Possible Causes
Stuck door switch, Misaligned door magnet, Shorted light relay on main PCB, Faulty user interface light control
How to Fix / Troubleshooting
Safety: Unplug the unit before working near the light fixture or control board. The light lens and bulb may be hot.
Steps:
- 1. Check door closure: Ensure the door closes fully and is not hitting shelves or bottles.
- 2. Test door switch: Locate the door switch (mechanical plunger or magnetic reed). Manually actuate it and see if the light turns off. If not, the switch or control is faulty.
- 3. Inspect magnet alignment: For magnetic switches, verify the door magnet lines up with the sensor. Adjust hinges or replace magnet if needed.
- 4. Replace door switch: If the switch does not change state when actuated, replace the door switch assembly.
- 5. Control board check: If the switch works but the light remains on, the light relay or transistor on the main PCB may be stuck. Replace the main control board.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door Switch Assembly
Check Price on Amazon
We may earn a commission from links on this page.