Lighting Circuit Failure
Interior light not working but cooler otherwise operates normally.
Advertisements
Possible Causes
Burned-out LED module, Faulty door switch or reed sensor, Broken light wiring harness
How to Fix / Troubleshooting
Safety first: Unplug the unit before removing light covers or accessing wiring.
Steps:
- 1. Test door switch: Open and close the door while observing the light. On models with a magnetic switch, use a magnet near the frame to simulate door closure.
- 2. Inspect LED module: Remove the light cover and check for visible damage or moisture.
- 3. Replace LED module: Install a new Liebherr LED light module if the old one is dark or visibly damaged.
- 4. Check wiring: If the new module does not light, inspect the harness and connectors back to the control board. Repair or replace as needed.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
LED Light Module / Door Switch