Liebherr Compressor or Sealed System Failure

Wine cooler not cooling at all; interior at room temperature; display and lights work but no cold air.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor, Major refrigerant leak in sealed system, Blocked capillary tube or filter drier, Faulty main control board not powering compressor

How to Fix / Troubleshooting

Safety first: Unplug the appliance before removing rear covers. Do not attempt to open the sealed refrigeration system yourself.

Steps:

  • 1. Listen for compressor: With the unit plugged in, listen at the back. If the compressor is silent and not vibrating, it may not be receiving power or may be failed.
  • 2. Check condenser temperature: Carefully feel the condenser coils (they should be warm when the compressor runs). If they remain cold, the compressor is not operating.
  • 3. Basic electrical checks: Verify that the thermostat is not set to OFF and that no demo mode is active. Perform a power reset.
  • 4. Visual inspection: Remove the rear lower cover and look for burnt wiring, loose connectors, or a tripped overload device.
  • 5. Call a professional: If the compressor attempts to start and clicks off, or runs but no cooling occurs, a sealed system issue is likely. Only an F-gas certified technician should diagnose and repair refrigerant leaks, replace compressors, or open the sealed system.
Advertisements

Repair Difficulty

Professional Required 5/5