Dual-zone SMEG wine cooler: one zone cools correctly while the other zone is warm or not cooling.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Unplug the appliance before accessing interior panels or fans.
Steps to diagnose a warm zone:
- Compare zones: Verify that the set temperatures are correct for both zones and that doors are sealing properly.
- Check fan operation: Listen for the evaporator fan in the warm zone when the compressor is running. If silent, access and test/replace the fan motor.
- Inspect air ducts: Ensure that any air passages between zones are not blocked by bottles or debris.
- Test zone sensor: Measure the NTC sensor for the warm zone and replace if out of specification.
- Control PCB: If hardware is good but the zone never cools, the control PCB may not be energizing that zone's valve or circuit and may need replacement.
Note: Some SMEG dual-zone models share a compressor but use separate fans and sensors; correct diagnosis depends on the specific design.
Repair Difficulty
Required Part