Intergas
Intergas Furnaces Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
Symptom
Boiler/furnace does not start; the display shows code 0, and no ignition attempt is heard.
No Heat Demand / Standby Lockout
1
Furnace attempts to start but locks out with code 1; no flame is established.
Ignition Failure / No Flame Detected
10
The boiler shows Code 10 and will not fire; the fan may not start.
Fan Speed / Tachometer Fault
11
Code 11 is displayed, the boiler locks out, and the issue may be related to gas valve control.
Gas Valve Control / Modulation Error
12
The boiler intermittently shows Code 12; resets may temporarily restore operation.
Low System Water Pressure / Flow Fault
13
Code 13 is displayed, the boiler stops, and the issue may be associated with condensate issues.
Condensate Drain / Siphon Fault
14
The boiler shows Code 14, has no heating output, and the pump may not run.
Pump Fault / No Circulation
15
Code 15 appears, the boiler locks out, and the issue may be related to flue gas temperature.
Flue Gas Temperature Overlimit
16
The boiler shows Code 16, along with erratic behavior of the display and controls.
Control PCB / Internal Error
17
Code 17 is displayed, and the boiler does not respond correctly to external controls.
Communication Fault with Room Thermostat / OpenTherm
18
The boiler shows Code 18, which may be associated with low voltage or power issues.
Mains Supply / Low Voltage Fault
19
Code 19 displayed, boiler fails to start, may be related to the safety chain.
Safety Circuit Open (Limit Switch / Safety Chain Fault)
2
Furnace locks out with code 2 shortly after ignition; the burner shuts down.
Flame Loss During Operation
3
The display shows code 3; the furnace does not start, and the fan may run briefly.
Air Pressure / Fan Fault
4
Boiler shows code 4 and will not fire; this may occur intermittently.
Flow Sensor / NTC Fault (Heating Circuit)
5
The display shows code 5; the boiler shuts down due to high temperature.
Overheat Thermostat / Safety Cut-out Tripped
6
Code 6 is displayed; the boiler will not run and may be accompanied by a very high temperature reading.
Flow Temperature Sensor Overrange / Short Circuit
7
Code 7 is displayed; the boiler does not respond to hot water demand.
DHW Temperature Sensor / NTC Fault
8
Code 8 is displayed; the boiler cycles rapidly or does not modulate correctly.
Flow Sensor / Turbine Fault (DHW Flow Detection)
9
Code 9 appears, the boiler stops, and may show abnormal temperature readings.
Return Temperature Sensor / NTC Fault
Symptom
Boiler display is blank, no lights; the unit is completely dead.
No Power / Dead Appliance
Symptom
Boiler display works, but buttons or controls do not respond properly.
User Interface / Control Panel Fault
Symptom
Boiler fan runs, but the burner does not light, and no error code is displayed.
No Ignition Without Fault Code
Symptom
Boiler frequently locks out during very cold weather; the condensate pipe outside is icy.
Frozen Condensate Pipe
Symptom
Boiler ignites with a loud bang or pop.
Delayed Ignition
Symptom
Boiler loses pressure over time; the user must frequently top up the system.
Chronic Pressure Loss
Symptom
Boiler pressure rises rapidly when heating, and the relief valve discharges water.
Over-Pressurization / Expansion Vessel Failure
Symptom
Boiler runs, but some radiators stay cold or only partially warm.
Poor Circulation / System Balancing Issue
Symptom
Boiler will not start after summer; pump or fan appears stuck.
Seized Components After Long Inactivity
Symptom
Condensate water dripping from flue joints or the boiler casing.
Condensate Leakage from Flue System
Symptom
Furnace frequently cycles on and off, resulting in short burner run times and unstable room temperature.
Short Cycling
Symptom
Furnace is very noisy during operation, with whistling or roaring sounds from the burner area.
Combustion Noise / Burner Resonance
Symptom
Furnace makes loud banging or knocking noises when starting or stopping.
Water Hammer / Thermal Expansion Noise
Symptom
Furnace or boiler casing vibrates excessively, with humming felt through walls.
Mechanical Vibration / Imbalance
Symptom
Furnace runs but radiators or air handlers do not get hot enough; long heat-up times.
Underheating / Insufficient Output
Symptom
Radiators get hot, but domestic hot water temperature fluctuates or is too cold.
Poor DHW Performance
Symptom
Soot or scorch marks around the flue terminal or boiler casing.
Incomplete Combustion / Flue Gas Spillage
Symptom
Strong smell of gas near the Intergas furnace/boiler.
Gas Leak
Symptom
Water leaking from the bottom of the Intergas furnace/boiler casing.
Internal Water Leak
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| – |
Boiler/furnace does not start; the display shows code 0, and no ignition attempt is heard.
|
No Heat Demand / Standby Lockout | View Details |
| 1 |
Furnace attempts to start but locks out with code 1; no flame is established.
|
Ignition Failure / No Flame Detected | View Details |
| 10 |
The boiler shows Code 10 and will not fire; the fan may not start.
|
Fan Speed / Tachometer Fault | View Details |
| 11 |
Code 11 is displayed, the boiler locks out, and the issue may be related to gas valve control.
|
Gas Valve Control / Modulation Error | View Details |
| 12 |
The boiler intermittently shows Code 12; resets may temporarily restore operation.
|
Low System Water Pressure / Flow Fault | View Details |
| 13 |
Code 13 is displayed, the boiler stops, and the issue may be associated with condensate issues.
|
Condensate Drain / Siphon Fault | View Details |
| 14 |
The boiler shows Code 14, has no heating output, and the pump may not run.
|
Pump Fault / No Circulation | View Details |
| 15 |
Code 15 appears, the boiler locks out, and the issue may be related to flue gas temperature.
|
Flue Gas Temperature Overlimit | View Details |
| 16 |
The boiler shows Code 16, along with erratic behavior of the display and controls.
|
Control PCB / Internal Error | View Details |
| 17 |
Code 17 is displayed, and the boiler does not respond correctly to external controls.
|
Communication Fault with Room Thermostat / OpenTherm | View Details |
| 18 |
The boiler shows Code 18, which may be associated with low voltage or power issues.
|
Mains Supply / Low Voltage Fault | View Details |
| 19 |
Code 19 displayed, boiler fails to start, may be related to the safety chain.
|
Safety Circuit Open (Limit Switch / Safety Chain Fault) | View Details |
| 2 |
Furnace locks out with code 2 shortly after ignition; the burner shuts down.
|
Flame Loss During Operation | View Details |
| 3 |
The display shows code 3; the furnace does not start, and the fan may run briefly.
|
Air Pressure / Fan Fault | View Details |
| 4 |
Boiler shows code 4 and will not fire; this may occur intermittently.
|
Flow Sensor / NTC Fault (Heating Circuit) | View Details |
| 5 |
The display shows code 5; the boiler shuts down due to high temperature.
|
Overheat Thermostat / Safety Cut-out Tripped | View Details |
| 6 |
Code 6 is displayed; the boiler will not run and may be accompanied by a very high temperature reading.
|
Flow Temperature Sensor Overrange / Short Circuit | View Details |
| 7 |
Code 7 is displayed; the boiler does not respond to hot water demand.
|
DHW Temperature Sensor / NTC Fault | View Details |
| 8 |
Code 8 is displayed; the boiler cycles rapidly or does not modulate correctly.
|
Flow Sensor / Turbine Fault (DHW Flow Detection) | View Details |
| 9 |
Code 9 appears, the boiler stops, and may show abnormal temperature readings.
|
Return Temperature Sensor / NTC Fault | View Details |
| – |
Boiler display is blank, no lights; the unit is completely dead.
|
No Power / Dead Appliance | View Details |
| – |
Boiler display works, but buttons or controls do not respond properly.
|
User Interface / Control Panel Fault | View Details |
| – |
Boiler fan runs, but the burner does not light, and no error code is displayed.
|
No Ignition Without Fault Code | View Details |
| – |
Boiler frequently locks out during very cold weather; the condensate pipe outside is icy.
|
Frozen Condensate Pipe | View Details |
| – |
Boiler ignites with a loud bang or pop.
|
Delayed Ignition | View Details |
| – |
Boiler loses pressure over time; the user must frequently top up the system.
|
Chronic Pressure Loss | View Details |
| – |
Boiler pressure rises rapidly when heating, and the relief valve discharges water.
|
Over-Pressurization / Expansion Vessel Failure | View Details |
| – |
Boiler runs, but some radiators stay cold or only partially warm.
|
Poor Circulation / System Balancing Issue | View Details |
| – |
Boiler will not start after summer; pump or fan appears stuck.
|
Seized Components After Long Inactivity | View Details |
| – |
Condensate water dripping from flue joints or the boiler casing.
|
Condensate Leakage from Flue System | View Details |
| – |
Furnace frequently cycles on and off, resulting in short burner run times and unstable room temperature.
|
Short Cycling | View Details |
| – |
Furnace is very noisy during operation, with whistling or roaring sounds from the burner area.
|
Combustion Noise / Burner Resonance | View Details |
| – |
Furnace makes loud banging or knocking noises when starting or stopping.
|
Water Hammer / Thermal Expansion Noise | View Details |
| – |
Furnace or boiler casing vibrates excessively, with humming felt through walls.
|
Mechanical Vibration / Imbalance | View Details |
| – |
Furnace runs but radiators or air handlers do not get hot enough; long heat-up times.
|
Underheating / Insufficient Output | View Details |
| – |
Radiators get hot, but domestic hot water temperature fluctuates or is too cold.
|
Poor DHW Performance | View Details |
| – |
Soot or scorch marks around the flue terminal or boiler casing.
|
Incomplete Combustion / Flue Gas Spillage | View Details |
| – |
Strong smell of gas near the Intergas furnace/boiler.
|
Gas Leak | View Details |
| – |
Water leaking from the bottom of the Intergas furnace/boiler casing.
|
Internal Water Leak | View Details |
No matching codes found
Advertisements