Monument Grills
Auger Mechanical Noise / Bearing Wear
Loud grinding or squealing noise from hopper area during operation
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dry or worn auger motor bearings, Bent auger shaft rubbing tube, Foreign object in auger, Misaligned auger motor mount
How to Fix / Troubleshooting
Safety first: Unplug the grill and ensure the auger is not moving before inspection.
- Step 1 – Empty hopper: Remove pellets to expose the auger intake. Check for foreign objects.
- Step 2 – Inspect auger alignment: Access the auger motor and verify that the motor mount is secure and the shaft is centered in the tube.
- Step 3 – Remove and inspect auger: Detach the motor and pull the auger from the tube. Look for bends, scoring, or debris. Clean and lightly sand rough spots.
- Step 4 – Lubrication: Do not use oil inside the auger tube. If the motor bearings are noisy, replace the Monument auger motor rather than lubricating.
- Step 5 – Reassemble: Reinstall the auger and motor, ensuring smooth rotation by hand before powering up.