AEG

AEG Ranges & Cooktops Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
d
Display shows 'd' or 'demo' and zones heat only very weakly or not at all
Demo Mode Activated
E0
The induction hob will not operate; the display shows E0 on one or more zones.
Pan Detection Failure
E1
An induction hob zone shuts down shortly after switching on, and the display shows E1.
Cookware Overheating or Dry-Boil Protection
E2
An induction hob zone stops and displays E2 during cooking.
Induction Zone Overheating Protection
E3
The induction hob displays E3 and will not heat on one or more zones.
Supply Voltage Too High
E4
The induction hob displays E4, and the zone does not heat.
Supply Voltage Too Low or Power Module Undervoltage
E5
Induction hob shows E5 and shuts down or refuses to start
Hob Electronics Overheating
E6
Induction hob displays E6 and zones are disabled
Internal Communication Error Between User Interface and Power Module
E7
Induction hob shows E7 on a specific zone, no heating
Induction Coil or Power Stage Failure
E8
Induction hob displays E8 and beeps, zone cannot be used
Configuration or Calibration Error
E9
Induction hob shows E9 and shuts down all zones
Internal Electronics Fault / Power Module Failure
Er03
Induction or ceramic hob shows Er03 and beeps, controls locked
Control Panel Contaminated or Continuous Key Press Detected
Er22
Hob displays Er22 and does not respond to touch
Touch Control Calibration Error
Er47
Induction hob shows Er47, and the affected zone is disabled.
Power Module Overcurrent or Short-Circuit Protection
F
Induction hob or ceramic hob shows flashing 'F' on a zone display
No Pan Detected / Incompatible Cookware
F1
AEG gas hob with electronic ignition shows F1, and burners will not ignite.
Ignition System Fault
F2
AEG gas hob shows F2, burners shut off automatically.
Flame Supervision Device (FSD) / Thermocouple Fault
F3
AEG gas hob shows F3, and ignition clicks continuously.
Stuck Ignition Switch or Wet Control
F4
AEG gas hob shows F4, and the burner shuts off shortly after ignition.
Flame Detection Error
F5
AEG gas hob shows F5, and all burners are disabled.
Gas Safety System General Fault
L
Hob display shows 'L' and controls do not respond
Child Lock / Control Lock Activated
Symptom
Burner on gas hob will not ignite; no clicking sound
Ignition System Inoperative
Symptom
Gas hob burner ignites but goes out when the knob is released
Flame Failure Device Not Holding
Symptom
Gas hob burner produces a yellow, sooty, or uneven flame
Poor Combustion / Burner Contamination
Symptom
Gas hob ignition keeps clicking even after the flame is lit
Stuck Ignition Switch / Continuous Spark
Symptom
Glass ceramic surface cracked or shattered
Glass Hob Top Damage
Symptom
Hob causes the circuit breaker or RCD to trip when turned on
Electrical Short or Earth Leakage
Symptom
Hob controls are unresponsive; you cannot change the power level or turn zones on.
Touch Control Panel Failure
Symptom
Hob emits a burning smell or smoke from vents during operation
Overheating or Component Failure
Symptom
Hob makes a loud buzzing or humming noise when using induction zones
Induction Acoustic Noise / Coil Vibration
Symptom
Hob surface around zones discolored or stained
Cosmetic Damage / Heat Staining
Symptom
Hob turns itself off during cooking without an error code.
Overheating or Auto-Safety Shutoff
Symptom
Induction hob does not power on at all; no lights or display.
No Power / Dead Appliance
Symptom
Induction hob intermittently shuts off when using multiple zones at high power
Power Management / Load Limitation
Symptom
Induction or ceramic hob powers on, but an individual zone will not heat.
Single Cooking Zone Failure
Symptom
Residual heat indicator stays on even when zone is cold
Residual Heat Sensor or Logic Fault
Symptom
Strong gas smell around AEG gas hob during or after use
Gas Leak or Incomplete Combustion
Symptom
Timer function on hob does not work or zones do not switch off when timer ends
Timer Control Fault
Advertisements