E17
Hisense
Low Water Pressure / Slow Fill Detection
Washer-dryer displays E17, often associated with low water pressure or a slow fill.
Advertisements
Possible Causes
Partially closed water tap, Clogged inlet filters at the Hisense valve, Long or restricted inlet hoses, Failing water inlet valve coil
How to Fix / Troubleshooting
Safety first: Turn off the water supply and unplug the unit before disconnecting hoses.
- Verify water pressure: Open a nearby faucet to confirm strong water flow. If household pressure is low, contact your water supplier.
- Check taps and hoses: Ensure taps are fully open. Inspect hoses for kinks or restrictions. Replace old or internally collapsed hoses.
- Clean inlet filters: Remove hoses from the Hisense water inlet valve and clean the mesh filters as described for E1.
- Test fill: Reconnect and run a quick wash. If the fill remains slow and E17 reappears, the inlet valve may be weak and should be replaced.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Hisense Water Inlet Valve Assembly
Check Price on Amazon
We may earn a commission from links on this page.