A1
Worcester Bosch
Condensate Drain Blocked
Boiler displays A1 and stops, often accompanied by gurgling sounds; condensate may not be draining.
Advertisements
Possible Causes
Frozen external condensate pipe, Blocked condensate trap, Sagging or incorrectly sloped condensate pipework
How to Fix / Troubleshooting
Safety first: Turn off power before working near water or condensate pipework. Do not use naked flames to thaw pipes.
User actions (safe):
- Locate the external condensate pipe (usually white plastic) and check for freezing in cold weather.
- Thaw a frozen pipe by pouring warm (not boiling) water over the outside of the pipe or using warm towels.
- Once thawed, press the reset button to restart the boiler.
Engineer actions:
- Remove and clean the condensate trap, ensuring all debris and sludge are cleared; refill with clean water.
- Check the internal and external condensate pipework for correct fall (slope) and secure fixings; correct any sags or backfalls.
- Insulate external condensate pipework to reduce risk of freezing.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condensate Trap