E13
Grizzl-E Pilot Duty Cycle / Current Limit Encoding Error

Charger LEDs show an error; the vehicle indicates ‘Pilot error’ or ‘EVSE error’; this occurs with multiple vehicles.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect DIP switch configuration for the current limit, Failed PWM generator on the control board, Short between pilot and ground, Damaged pilot resistor network.

How to Fix / Troubleshooting

Safety: De‑energize the unit before opening.

  • Verify DIP switch settings: Compare the DIP switch positions inside the Grizzl‑E to the installation manual to confirm the desired maximum current. Correct any misconfiguration.
  • Inspect pilot wiring: Ensure the pilot conductor is not pinched or contacting ground inside the enclosure.
  • Check for contamination: Dirt or moisture bridging the pilot pin to ground in the J1772 connector can distort the duty cycle. Clean and dry the connector thoroughly.
  • Resolution: If settings and wiring are correct but E13 persists with different vehicles, the PWM generator or resistor network on the main control board is likely defective and the board should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements