Comfortmaker
Comfortmaker Air Conditioners Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
E1
Indoor unit display shows E1, and cooling stops or runs briefly then shuts down.
Indoor Room Temperature Sensor (Thermistor) Fault
E2
Indoor unit shows E2, and the system stops cooling or runs with poor temperature control.
Indoor Evaporator Coil Temperature Sensor Fault
E3
Comfortmaker indoor display shows E3, and the outdoor unit does not start or shuts down quickly.
Outdoor Coil Temperature Sensor Fault
E4
Indoor unit displays E4, and the system stops or runs briefly then shuts down, often during heating or defrost cycles on heat pump models.
Discharge (Compressor) Temperature Sensor Fault
E5
Indoor unit displays E5, and the outdoor unit does not start or shuts down; this may occur at startup.
Communication Fault Between Indoor and Outdoor Units
E6
Indoor unit displays E6, and the compressor does not run or cycles off quickly.
Compressor Overload / Current Protection Trip
E7
Indoor unit displays E7, and the system will not run or only the fan operates.
Indoor Fan Motor Fault (ECM/BLDC Motor Error)
E8
Indoor unit displays E8, and the system shuts down, often after running for a short time.
High Pressure Protection / Overheat Protection
E9
Indoor unit displays E9, and the unit may not respond to thermostat or remote commands.
EEPROM / Control Board Memory Error
F0
Display shows F0, and the unit will not start or stops shortly after starting.
Refrigerant System Low Charge / Low Pressure Protection
F1
Display shows F1, and the unit may run erratically or not at all.
Indoor Ambient Sensor Out of Range (High/Low Temperature)
F2
Display shows F2, and the unit may shut down during cooling.
Evaporator Coil Freeze Protection / Low Coil Temperature
F3
Display shows F3, and the outdoor unit may not start or may short-cycle.
Outdoor Ambient Temperature Sensor Fault
F4
Display shows F4, and compressor operation is inhibited or erratic.
Compressor Discharge Over-Temperature Protection
F5
Display shows F5, and the unit may not defrost properly (heat pump models) or may shut down.
Defrost Sensor / Coil Sensor Fault
F6
Display shows F6, and compressor speed or operation is limited (inverter models).
Inverter Module Overcurrent / Drive Fault
F7
Display shows F7, and the unit may not respond to the thermostat or remote.
Communication Error with User Interface / Thermostat
F8
Display shows F8, and the unit may shut down or limit capacity.
Indoor Coil High Temperature / Overheat Protection
F9
Display shows F9, and the system may not start or may shut down unexpectedly.
Power Supply / Voltage Abnormality
Symptom
Comfortmaker air conditioner causes lights to dim or the breaker to trip when starting.
High Inrush Current / Electrical Overload
Symptom
Comfortmaker air conditioner emits a burning or electrical smell when running.
Overheating Electrical Component or Dust Burn-Off
Symptom
Comfortmaker air conditioner frequently freezes the outdoor coil in heat pump heating mode.
Defrost System Malfunction (Heat Pump)
Symptom
Comfortmaker air conditioner is very noisy outdoors; rattling, grinding, or squealing sounds.
Mechanical Noise from Outdoor Unit
Symptom
Comfortmaker air conditioner runs continuously and does not shut off even when the set temperature is reached.
Runaway Cooling / Thermostat or Control Stuck
Symptom
Comfortmaker air conditioner short cycles; turns on and off frequently without reaching the set temperature.
Short Cycling / Improper Capacity Control
Symptom
Comfortmaker indoor unit makes a loud squealing or grinding noise when running.
Indoor Blower Mechanical Failure
Symptom
Comfortmaker outdoor fan runs, but the compressor does not; no cooling.
Compressor Not Starting
Symptom
Comfortmaker outdoor unit makes a loud buzzing or humming sound, but the fan and compressor do not start.
Failed Start/Run Capacitor or Locked Compressor
Symptom
Comfortmaker system cools some rooms, but others remain warm; uneven cooling.
Air Distribution / Ductwork Imbalance
Symptom
Comfortmaker system emits a musty or moldy odor when running.
Biological Growth in Evaporator Coil or Drain Pan
Symptom
Comfortmaker thermostat shows a cooling call, but the outdoor unit does not receive a 24V signal (no Y call at the condenser).
Control Signal Interruption
Symptom
Ice forming on the Comfortmaker indoor evaporator coil or suction line; reduced airflow and cooling.
Evaporator Coil Icing
Symptom
Outdoor Comfortmaker condenser runs, but the indoor blower does not run; little or no air comes from the vents.
Indoor Blower Motor or Control Failure
Symptom
The Comfortmaker air conditioner runs but does not cool well; supply air is only slightly cooler than room air.
Poor Cooling Performance
Symptom
The Comfortmaker system will not start at all; there is no indoor or outdoor operation.
No Power / Control Circuit Failure
Symptom
The indoor blower runs, but the outdoor Comfortmaker condenser does not start; warm air comes from the vents.
Outdoor Unit Not Running
Symptom
Water leaking from the indoor Comfortmaker air handler or from the ceiling near the air handler.
Condensate Drainage Failure
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E1 |
Indoor unit display shows E1, and cooling stops or runs briefly then shuts down.
|
Indoor Room Temperature Sensor (Thermistor) Fault | View Details |
| E2 |
Indoor unit shows E2, and the system stops cooling or runs with poor temperature control.
|
Indoor Evaporator Coil Temperature Sensor Fault | View Details |
| E3 |
Comfortmaker indoor display shows E3, and the outdoor unit does not start or shuts down quickly.
|
Outdoor Coil Temperature Sensor Fault | View Details |
| E4 |
Indoor unit displays E4, and the system stops or runs briefly then shuts down, often during heating or defrost cycles on heat pump models.
|
Discharge (Compressor) Temperature Sensor Fault | View Details |
| E5 |
Indoor unit displays E5, and the outdoor unit does not start or shuts down; this may occur at startup.
|
Communication Fault Between Indoor and Outdoor Units | View Details |
| E6 |
Indoor unit displays E6, and the compressor does not run or cycles off quickly.
|
Compressor Overload / Current Protection Trip | View Details |
| E7 |
Indoor unit displays E7, and the system will not run or only the fan operates.
|
Indoor Fan Motor Fault (ECM/BLDC Motor Error) | View Details |
| E8 |
Indoor unit displays E8, and the system shuts down, often after running for a short time.
|
High Pressure Protection / Overheat Protection | View Details |
| E9 |
Indoor unit displays E9, and the unit may not respond to thermostat or remote commands.
|
EEPROM / Control Board Memory Error | View Details |
| F0 |
Display shows F0, and the unit will not start or stops shortly after starting.
|
Refrigerant System Low Charge / Low Pressure Protection | View Details |
| F1 |
Display shows F1, and the unit may run erratically or not at all.
|
Indoor Ambient Sensor Out of Range (High/Low Temperature) | View Details |
| F2 |
Display shows F2, and the unit may shut down during cooling.
|
Evaporator Coil Freeze Protection / Low Coil Temperature | View Details |
| F3 |
Display shows F3, and the outdoor unit may not start or may short-cycle.
|
Outdoor Ambient Temperature Sensor Fault | View Details |
| F4 |
Display shows F4, and compressor operation is inhibited or erratic.
|
Compressor Discharge Over-Temperature Protection | View Details |
| F5 |
Display shows F5, and the unit may not defrost properly (heat pump models) or may shut down.
|
Defrost Sensor / Coil Sensor Fault | View Details |
| F6 |
Display shows F6, and compressor speed or operation is limited (inverter models).
|
Inverter Module Overcurrent / Drive Fault | View Details |
| F7 |
Display shows F7, and the unit may not respond to the thermostat or remote.
|
Communication Error with User Interface / Thermostat | View Details |
| F8 |
Display shows F8, and the unit may shut down or limit capacity.
|
Indoor Coil High Temperature / Overheat Protection | View Details |
| F9 |
Display shows F9, and the system may not start or may shut down unexpectedly.
|
Power Supply / Voltage Abnormality | View Details |
| – |
Comfortmaker air conditioner causes lights to dim or the breaker to trip when starting.
|
High Inrush Current / Electrical Overload | View Details |
| – |
Comfortmaker air conditioner emits a burning or electrical smell when running.
|
Overheating Electrical Component or Dust Burn-Off | View Details |
| – |
Comfortmaker air conditioner frequently freezes the outdoor coil in heat pump heating mode.
|
Defrost System Malfunction (Heat Pump) | View Details |
| – |
Comfortmaker air conditioner is very noisy outdoors; rattling, grinding, or squealing sounds.
|
Mechanical Noise from Outdoor Unit | View Details |
| – |
Comfortmaker air conditioner runs continuously and does not shut off even when the set temperature is reached.
|
Runaway Cooling / Thermostat or Control Stuck | View Details |
| – |
Comfortmaker air conditioner short cycles; turns on and off frequently without reaching the set temperature.
|
Short Cycling / Improper Capacity Control | View Details |
| – |
Comfortmaker indoor unit makes a loud squealing or grinding noise when running.
|
Indoor Blower Mechanical Failure | View Details |
| – |
Comfortmaker outdoor fan runs, but the compressor does not; no cooling.
|
Compressor Not Starting | View Details |
| – |
Comfortmaker outdoor unit makes a loud buzzing or humming sound, but the fan and compressor do not start.
|
Failed Start/Run Capacitor or Locked Compressor | View Details |
| – |
Comfortmaker system cools some rooms, but others remain warm; uneven cooling.
|
Air Distribution / Ductwork Imbalance | View Details |
| – |
Comfortmaker system emits a musty or moldy odor when running.
|
Biological Growth in Evaporator Coil or Drain Pan | View Details |
| – |
Comfortmaker thermostat shows a cooling call, but the outdoor unit does not receive a 24V signal (no Y call at the condenser).
|
Control Signal Interruption | View Details |
| – |
Ice forming on the Comfortmaker indoor evaporator coil or suction line; reduced airflow and cooling.
|
Evaporator Coil Icing | View Details |
| – |
Outdoor Comfortmaker condenser runs, but the indoor blower does not run; little or no air comes from the vents.
|
Indoor Blower Motor or Control Failure | View Details |
| – |
The Comfortmaker air conditioner runs but does not cool well; supply air is only slightly cooler than room air.
|
Poor Cooling Performance | View Details |
| – |
The Comfortmaker system will not start at all; there is no indoor or outdoor operation.
|
No Power / Control Circuit Failure | View Details |
| – |
The indoor blower runs, but the outdoor Comfortmaker condenser does not start; warm air comes from the vents.
|
Outdoor Unit Not Running | View Details |
| – |
Water leaking from the indoor Comfortmaker air handler or from the ceiling near the air handler.
|
Condensate Drainage Failure | View Details |