E16
Andersen Internal Energy Meter Communication Failure

Charger displays E16; app reports 'Meter Communication Error' and energy usage is not logged correctly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose communication harness between the main control PCB and the internal kWh meter, Failed internal energy meter module, Firmware mismatch between the meter and controller, Electrical noise on the internal bus

How to Fix / Troubleshooting

Safety first: Charging may still function, but billing/monitoring accuracy is affected. Do not open the unit while powered.

User steps:

  • Power cycle the charger and check if energy readings resume in the app.
  • Ensure the app is updated to the latest version.

If E16 persists:

  • A technician should isolate power, open the unit, and reseat the low‑voltage connectors between the main control PCB and the internal energy meter.
  • If communication is not restored, replace the internal meter module or main control PCB as per Andersen documentation.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Internal Energy Meter Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements