E011
Alfen Network Communication / Ethernet Fault

E011 is displayed; the charger cannot connect to the back-office or app, and remote control features fail.

Advertisements

Possible Causes

Unplugged or damaged Ethernet cable, Incorrect IP/network configuration, Failed Ethernet port on the Alfen communication board, Router or switch blocking outbound connections

How to Fix / Troubleshooting

Safety first: Network troubleshooting does not usually require power isolation, but isolate power if you open the charger enclosure.

  • Step 1 – Check physical connection: Verify that the Ethernet cable is firmly plugged into both the charger and the router/switch. Inspect it for visible damage.
  • Step 2 – Test cable: Use a known-good Ethernet cable or test the existing cable with a cable tester.
  • Step 3 – Verify router settings: Ensure the router provides DHCP or that the static IP configured in the Alfen charger is correct (IP, subnet, gateway, DNS).
  • Step 4 – Ping test: From a PC on the same network, attempt to ping the charger’s IP address. If unreachable, recheck the network settings in the charger via the local interface.
  • Step 5 – Check firewall/outbound rules: Confirm that outbound ports required by Alfen’s back-office are not blocked by the router or firewall.
  • When to call a technician: If the local network is fine but E011 persists, the Ethernet interface on the communication board may be faulty and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Communication Board (Ethernet Interface)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements