E019
myenergi Communication Fault with Hub / Linked Devices

Zappi displays E019, charging disabled, often when linked with a myenergi hub or other myenergi devices.

Advertisements

Possible Causes

Lost RF link to myenergi hub, Incorrect device pairing, RF interference, Faulty RF module on Zappi PCB.

How to Fix / Troubleshooting

Safety first: Communication faults do not usually affect electrical safety but may affect smart features.

  • 1. Check hub status: Ensure the myenergi hub is powered, connected to the network, and showing normal status LEDs.
  • 2. Verify pairing: In the Zappi menu, check that the hub and any linked devices (eddi, harvi, etc.) are correctly paired and visible.
  • 3. Reduce interference: Move the hub closer to the Zappi or away from large metal objects and other RF sources (Wi-Fi routers, microwaves).
  • 4. Re-pair devices: Remove and re-add the Zappi in the hub/app, following myenergi’s pairing procedure.
  • 5. Firmware update: Update firmware on both Zappi and hub to the latest versions.
  • 6. If RF module is faulty: Persistent E019 with good signal and correct pairing may indicate a failed RF module on the Zappi PCB, requiring board replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

RF Communication Module (on Main PCB)
Check Price on Amazon

We may earn a commission from links on this page.